RUNNER LINK Gateway Configuring the Runner Link
3. On
the Runner Link board, press the Config button for minimum of 5
seconds. (See figure 3)
The red FAIL LED lights and then after 5 seconds the green NET LED
lights as well and the green SYSTEM LED starts to blink. There is an
audible beep from your PC (acknowledgment) and the FAIL and NET
LEDS turn off. The screen then is populated with the default IP addresses
from the board.
4. Cha
nge the Authorized PC IP address to the normal working IP of your
PC.
NOTES
- This IP address MUST be used for maintaining the alarm system.
- For security concerns the screen and CONFIG button are disabled
after approximately 45 seconds. To continue, close the screen and
open the program again.
5. In the IP Runner link pane, select the IP mode and check the correct box
required for the network that the Runner Link is connected to.
If a static address is needed all the required information must be entered
manually. Or check the box to obtain an IP address automatically from
DHCP
6. Direct connect – check the box to Enable non-authorized connects to
RUNNER panel from any PC regardless the authorized PC (192.168.0.5)
via the internet network, and provide Password for security access.
7. Enable tamper – check the box if alarm tamper message required on
RUNNER's LCD display generated from RUNNER link module.
8. Disable Ack – check the box if both TCP/IP and PSTN transmission are
simultaneously required, otherwise TCP/IP transmit only
9. Receiv
ers –insert if required the receiver server's IP address (optional up
to 4 receiver servers)
11